0

Nanolab 200

Nanolab 200
Nanolab 200
Price And Quantity
  • Piece/Pieces
  • 1
  • Piece/Pieces,
  • 475000 INR
    Product Specifications
    • ABS Plastic
    • For Hospital amd Clinic Purpose
    • Chemistry Analyzer
    Product Description

    Overview

    Fully Automated Clinical Chemistry Analyzer.

    Features

    • Real performance through constant 200 test/ hour throughput with on board laundry.
    • Complete consolidation for wide range of assays suited to variety of laboratory types.
    • Accurate detection through versatile optics design (Holographic Grating Photometer).
    • Accurate result precision ensured by positive displacement ceramic piston syringe.
    • Long on board stability ensured by 66 shared refrigerated reagent carousels.

    TECHNICAL SPECIFICATIONS

    Sample Unit

    • Sample Tray - 40 Sample Positions
    • Sample Tube – Micro cup & test tube & blood collection tube can be used.
    • Sample Volume – 2-30µL, step by 0.lµL
    • Sample - 0.1 sample level detection, timely tracking for sample
    • volume. Collision avoidance
    • Sample Barcode – Optional

    Reagent Unit

    • Reagent Tray - 80 reagent Positions (40 for Rl & 40 for R2), Non-stop cooling system with peltier pad inside, 24 hours 2°C-14"C, open system, could accept any reagent.
    • Reagent Volume – 20-300µL, step by 1 µL
    • Reagent Needle – Reagent volume detection, timely tracking for reagent volume. Collision avoidance.
    • Reagent Barcode – Optional

    Operating System

    • Operation System - Indices, Windows XP, Windows 7, Windows 8, Windows 10
    • Data Processing - Automatic calibration, test combination, effective time management of reagents, serum, whole process de­tection, linear expansion of enzyme, blank deduction,dirty cuvette memory , cross infection prevention, patient info­rmation memory and association input, automatic report audit, data fuzzy query, report statistics and printing, refe­rence range grading, alarm information classification, user operation privilege classification management.
    • Report Printing - 6 formats optional, support custom pattern
    • Report Printing - TCP/IP network interface

    Optical System

    • Light Source - Halogen Lamp
    • Wavelength - 340nm; 405nm; 450nm; 505nm; 546nm; 578nm; 630nm; 700nm (4 more options)
    • Absorbance Range – 0-4.0 Abs
    • Resolution – 0.0001 Abs

    Working Condition

    • Power Supply - AC 110/220V ± 10%, 50/60 Hz, 650W
    • Water Consumption - 8L/hour(maximum)
    • Dimension weight – 870mm * 690mm * 740mm(L *W*H)
    • Weight – 80kgs

    Trade Information
    • 1 Per Week
    • 1-6 Week
    • All India
    Contact Us

    #3F, Third Floor, Uppals Plaza M6, Plot No. 6, Jasola District Center, New Delhi, Delhi, 110025, India
    Phone :91-11-41354650/41354651/41354652